Energy Performance Certificate

101 Fowlers Walk, W5 1BQ

EPC Report

Energy rating

Current: 44 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 37 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 84 Potential: 84
Field Value
LMK KEY 0310-2202-5170-2102-0441
ADDRESS1 101 Fowlers Walk
ADDRESS2
ADDRESS3
POSTCODE W5 1BQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-03-02
LOCAL AUTHORITY E09000009
CONSTITUENCY E14001207
COUNTY
LODGEMENT DATE 2022-03-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 398
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 869
HEATING COST POTENTIAL 365
HOT WATER COST CURRENT 158
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 82
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 101 Fowlers Walk
LOCAL AUTHORITY LABEL Ealing
CONSTITUENCY LABEL Ealing Central and Acton
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-03-04 08:57:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 12085815
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000007
Address display
Nation ew