Energy Performance Certificate

306 WYNCLIFFE GARDENS, PENTWYN, CARDIFF, CF23 7FA

EPC Report

Energy rating

Current: 73 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 72 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 85 Potential: 85
Field Value
LMK KEY 0303-3329-8002-1009-1502
ADDRESS1 306 WYNCLIFFE GARDENS
ADDRESS2 PENTWYN
ADDRESS3 CARDIFF
POSTCODE CF23 7FA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-01-07
LOCAL AUTHORITY W06000015
CONSTITUENCY W07000089
COUNTY
LODGEMENT DATE 2021-01-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 162
ENERGY CONSUMPTION POTENTIAL 68
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 138
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 379
HEATING COST POTENTIAL 398
HOT WATER COST CURRENT 154
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 95
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 306 WYNCLIFFE GARDENS, PENTWYN, CARDIFF
LOCAL AUTHORITY LABEL Cardiff
CONSTITUENCY LABEL Cardiff East
POSTTOWN CARDIFF
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2021-01-09 10:28:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10013083053
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew