Energy Performance Certificate

31 Severn Side South, DY12 2DX

EPC Report

Energy rating

Current: 60 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 50 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 83 Potential: 83
Field Value
LMK KEY 0300-2998-1130-2194-6985
ADDRESS1 31 Severn Side South
ADDRESS2
ADDRESS3
POSTCODE DY12 2DX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-07-18
LOCAL AUTHORITY E07000239
CONSTITUENCY E14001601
COUNTY
LODGEMENT DATE 2024-07-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 265
ENERGY CONSUMPTION POTENTIAL 85
CO2 EMISSIONS CURRENT 7.7
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 155
LIGHTING COST POTENTIAL 158
HEATING COST CURRENT 2493
HEATING COST POTENTIAL 1023
HOT WATER COST CURRENT 182
HOT WATER COST POTENTIAL 182
TOTAL FLOOR AREA 165
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31 Severn Side South
LOCAL AUTHORITY LABEL Wyre Forest
CONSTITUENCY LABEL Wyre Forest
POSTTOWN BEWDLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-07-19 10:11:28
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 100120719697
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000005
Address display
Nation ew