Energy Performance Certificate

23 Baxter Court, NR3 2SS

EPC Report

Energy rating

Current: 48 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 57 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 79 Potential: 79
Field Value
LMK KEY 0300-2980-2180-2392-2915
ADDRESS1 23 Baxter Court
ADDRESS2
ADDRESS3
POSTCODE NR3 2SS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-08-10
LOCAL AUTHORITY E07000148
CONSTITUENCY E14001408
COUNTY
LODGEMENT DATE 2022-08-16
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 327
ENERGY CONSUMPTION POTENTIAL 156
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1030
HEATING COST POTENTIAL 255
HOT WATER COST CURRENT 72
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 40
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.23
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23 Baxter Court
LOCAL AUTHORITY LABEL Norwich
CONSTITUENCY LABEL Norwich North
POSTTOWN NORWICH
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2022-08-16 13:31:02
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100090887791
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew