Energy Performance Certificate

Midtown Annex, Mockerkin, CA13 0ST

EPC Report

Energy rating

Current: 27 F | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 78 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 93 Potential: 93
Field Value
LMK KEY 0300-2809-8010-2020-8071
ADDRESS1 Midtown Annex
ADDRESS2 Mockerkin
ADDRESS3
POSTCODE CA13 0ST
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-09-21
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2020-09-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 510
ENERGY CONSUMPTION POTENTIAL 285
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1707
HEATING COST POTENTIAL 1166
HOT WATER COST CURRENT 241
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, wood pellets
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL bulk wood pellets
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Midtown Annex, Mockerkin
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN Cockermouth
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-09-24 14:15:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10008819115
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display