Energy Performance Certificate

5 Saffron Court, SG18 8DR

EPC Report

Energy rating

Current: 63 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 67 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 69 Potential: 69
Field Value
LMK KEY 0300-2787-4310-2197-7031
ADDRESS1 5 Saffron Court
ADDRESS2
ADDRESS3
POSTCODE SG18 8DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-09-13
LOCAL AUTHORITY E06000056
CONSTITUENCY E14001384
COUNTY
LODGEMENT DATE 2023-09-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 289
ENERGY CONSUMPTION POTENTIAL 269
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 109
HEATING COST CURRENT 769
HEATING COST POTENTIAL 267
HOT WATER COST CURRENT 584
HOT WATER COST POTENTIAL 217
TOTAL FLOOR AREA 42
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Saffron Court
LOCAL AUTHORITY LABEL Central Bedfordshire
CONSTITUENCY LABEL North Bedfordshire
POSTTOWN BIGGLESWADE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-09-13 16:11:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100080068004
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew