Energy Performance Certificate

131, Station Road, Keadby, DN17 3BP

EPC Report

Energy rating

Current: 42 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 22 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 47 Potential: 47
Field Value
LMK KEY 0293-2830-6483-9377-5915
ADDRESS1 131, Station Road
ADDRESS2 Keadby
ADDRESS3
POSTCODE DN17 3BP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-08-30
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001199
COUNTY
LODGEMENT DATE 2013-09-03
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 428
ENERGY CONSUMPTION POTENTIAL 219
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 111
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 1266
HEATING COST POTENTIAL 819
HOT WATER COST CURRENT 223
HOT WATER COST POTENTIAL 103
TOTAL FLOOR AREA 96
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, coal
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 131, Station Road, Keadby
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Doncaster East and the Isle of Axholme
POSTTOWN SCUNTHORPE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-09-03 10:37:35
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 200000869407
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew