Energy Performance Certificate

13, High Cross Drive, Rogerstone, NP10 9AB

EPC Report

Energy rating

Current: 53 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 47 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 81 Potential: 81
Field Value
LMK KEY 0290-2876-6143-9202-8945
ADDRESS1 13, High Cross Drive
ADDRESS2 Rogerstone
ADDRESS3
POSTCODE NP10 9AB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-04-06
LOCAL AUTHORITY W06000022
CONSTITUENCY W07000105
COUNTY
LODGEMENT DATE 2012-04-09
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 281
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 831
HEATING COST POTENTIAL 479
HOT WATER COST CURRENT 222
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 106
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 86
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.58
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13, High Cross Drive, Rogerstone
LOCAL AUTHORITY LABEL Newport
CONSTITUENCY LABEL Newport West and Islwyn
POSTTOWN NEWPORT
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2012-04-09 17:54:47
TENURE
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100100669161
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew