Energy Performance Certificate

2, Caroline Row, TR27 4EQ

EPC Report

Energy rating

Current: 36 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 20 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 80 Potential: 80
Field Value
LMK KEY 0288-5074-7245-2843-8924
ADDRESS1 2, Caroline Row
ADDRESS2
ADDRESS3
POSTCODE TR27 4EQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2017-05-08
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001148
COUNTY
LODGEMENT DATE 2017-05-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 561
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 95
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 1267
HEATING COST POTENTIAL 468
HOT WATER COST CURRENT 279
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 99
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Caroline Row
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL Camborne and Redruth
POSTTOWN HAYLE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-05-08 13:33:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100040102930
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000009
Address display