Energy Performance Certificate

3, MacMillan Way, Little Plumstead, NR13 5FE

EPC Report

Energy rating

Current: 80 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 80 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 81 Potential: 81
Field Value
LMK KEY 0278-9057-6381-9282-5970
ADDRESS1 3, MacMillan Way
ADDRESS2 Little Plumstead
ADDRESS3
POSTCODE NR13 5FE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-09-03
LOCAL AUTHORITY E07000144
CONSTITUENCY E14001136
COUNTY
LODGEMENT DATE 2012-09-04
TRANSACTION TYPE new dwelling
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 102
ENERGY CONSUMPTION POTENTIAL 98
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 444
HEATING COST POTENTIAL 449
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 145
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 47
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.14 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.28 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 47% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 3, MacMillan Way, Little Plumstead
LOCAL AUTHORITY LABEL Broadland
CONSTITUENCY LABEL Broadland and Fakenham
POSTTOWN NORWICH
CONSTRUCTION AGE BAND 2011
LODGEMENT DATETIME 2012-09-04 09:35:42
TENURE
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10014352367
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2012.csv
COUNTRY England
REGION E12000006
Address display
Nation ew