Energy Performance Certificate

Flat 1, Marlborough Court, Cranley Gardens, SM6 9PG

EPC Report

Energy rating

Current: 72 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 56 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 66 Potential: 66
Field Value
LMK KEY 0270-3930-3200-3237-7204
ADDRESS1 Flat 1
ADDRESS2 Marlborough Court
ADDRESS3 Cranley Gardens
POSTCODE SM6 9PG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-10-03
LOCAL AUTHORITY E09000029
CONSTITUENCY E14001153
COUNTY
LODGEMENT DATE 2023-10-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 331
ENERGY CONSUMPTION POTENTIAL 258
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 118
HEATING COST CURRENT 593
HEATING COST POTENTIAL 343
HOT WATER COST CURRENT 270
HOT WATER COST POTENTIAL 270
TOTAL FLOOR AREA 51
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1, Marlborough Court, Cranley Gardens
LOCAL AUTHORITY LABEL Sutton
CONSTITUENCY LABEL Carshalton and Wallington
POSTTOWN WALLINGTON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2023-10-03 20:34:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 5870088383
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew