Energy Performance Certificate

5, Rose Walk, Ridgewell, CO9 4SH

EPC Report

Energy rating

Current: 58 D | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 50 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 64 Potential: 64
Field Value
LMK KEY 0270-2818-7780-2820-2001
ADDRESS1 5, Rose Walk
ADDRESS2 Ridgewell
ADDRESS3
POSTCODE CO9 4SH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-08-28
LOCAL AUTHORITY E07000067
CONSTITUENCY E14001121
COUNTY
LODGEMENT DATE 2020-08-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 167
ENERGY CONSUMPTION POTENTIAL 108
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 7.0
LIGHTING COST CURRENT 174
LIGHTING COST POTENTIAL 130
HEATING COST CURRENT 1401
HEATING COST POTENTIAL 1124
HOT WATER COST CURRENT 111
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 230
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 66
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 66% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 5, Rose Walk, Ridgewell
LOCAL AUTHORITY LABEL Braintree
CONSTITUENCY LABEL Braintree
POSTTOWN HALSTEAD
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2020-08-28 16:37:21
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 41
LOW ENERGY FIXED LIGHT COUNT 27
UPRN 10006924096
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000006
Address display
Nation ew