Energy Performance Certificate

44 Winchester Drive, Midway, DE11 7LS

EPC Report

Energy rating

Current: 62 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 56 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 86 Potential: 86
Field Value
LMK KEY 0270-1203-0804-6626-0000
ADDRESS1 44 Winchester Drive
ADDRESS2 Midway
ADDRESS3
POSTCODE DE11 7LS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-03-26
LOCAL AUTHORITY E07000039
CONSTITUENCY E14001483
COUNTY
LODGEMENT DATE 2024-03-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 307
ENERGY CONSUMPTION POTENTIAL 96
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 101
HEATING COST CURRENT 1309
HEATING COST POTENTIAL 732
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 114
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 44 Winchester Drive, Midway
LOCAL AUTHORITY LABEL South Derbyshire
CONSTITUENCY LABEL South Derbyshire
POSTTOWN SWADLINCOTE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-03-27 14:24:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100030260006
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000004
Address display
Nation ew