Energy Performance Certificate

Apartment 1, Consort House, Princes Gate, 2-6 Homer Road, B91 3QQ

EPC Report

Energy rating

Current: 73 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 74 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 74 Potential: 74
Field Value
LMK KEY 0267-3831-7975-9621-4635
ADDRESS1 Apartment 1
ADDRESS2 Consort House, Princes Gate
ADDRESS3 2-6 Homer Road
POSTCODE B91 3QQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2019-03-29
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001479
COUNTY
LODGEMENT DATE 2019-03-29
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 186
ENERGY CONSUMPTION POTENTIAL 186
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 334
HEATING COST POTENTIAL 334
HOT WATER COST CURRENT 112
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 62
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.25 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.43 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Apartment 1, Consort House, Princes Gate, 2-6 Homer Road
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Solihull West and Shirley
POSTTOWN SOLIHULL
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2019-03-29 13:20:16
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10093967768
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2019.csv
COUNTRY England
REGION E12000005
Address display
Nation ew