Energy Performance Certificate

7c, Mamble Road, DY8 3SX

EPC Report

Energy rating

Current: 74 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 74 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 80 Potential: 80
Field Value
LMK KEY 0264-2882-6090-9528-5201
ADDRESS1 7c, Mamble Road
ADDRESS2
ADDRESS3
POSTCODE DY8 3SX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2018-01-22
LOCAL AUTHORITY E08000027
CONSTITUENCY E14001524
COUNTY
LODGEMENT DATE 2018-01-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 178
ENERGY CONSUMPTION POTENTIAL 137
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 326
HEATING COST POTENTIAL 286
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 70
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7c, Mamble Road
LOCAL AUTHORITY LABEL Dudley
CONSTITUENCY LABEL Stourbridge
POSTTOWN STOURBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-01-23 08:09:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 90103096
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000005
Address display
Nation ew