Energy Performance Certificate

54, Granville Terrace, Binchester, DL14 8AT

EPC Report

Energy rating

Current: 42 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 13 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 Current: 13 97 Potential: 97
Field Value
LMK KEY 0262-2830-7151-9191-9275
ADDRESS1 54, Granville Terrace
ADDRESS2 Binchester
ADDRESS3
POSTCODE DL14 8AT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-05-10
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001101
COUNTY
LODGEMENT DATE 2019-07-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 13
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 476
ENERGY CONSUMPTION POTENTIAL 125
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 170
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 793
HEATING COST POTENTIAL 433
HOT WATER COST CURRENT 444
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 62
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, coal
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54, Granville Terrace, Binchester
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL Bishop Auckland
POSTTOWN BISHOP AUCKLAND
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2019-07-24 15:24:49
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100110515070
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000001
Address display