Energy Performance Certificate

21b Fieldview Close, Exhall, CV7 9BJ

EPC Report

Energy rating

Current: 64 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 89 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 89 Potential: 89
Field Value
LMK KEY 0259-3062-1205-4796-0200
ADDRESS1 21b Fieldview Close
ADDRESS2 Exhall
ADDRESS3
POSTCODE CV7 9BJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2026-05-05
LOCAL AUTHORITY E07000219
CONSTITUENCY E14001400
COUNTY
LODGEMENT DATE 2026-05-11
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 89
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 181
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 38
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 813
HEATING COST POTENTIAL 525
HOT WATER COST CURRENT 369
HOT WATER COST POTENTIAL 368
TOTAL FLOOR AREA 41
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21b Fieldview Close, Exhall
LOCAL AUTHORITY LABEL Nuneaton and Bedworth
CONSTITUENCY LABEL North Warwickshire and Bedworth
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2026-05-11 21:45:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100070132171
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000005
Address display
Nation ew