Energy Performance Certificate
1 Old Brewery House, Potter Street, S80 2AQ
Energy rating
Current: 32 F | Potential: 81 B
Environmental impact (CO₂)
Current: 41
| Potential: 69
| Field | Value |
|---|---|
| LMK KEY | 0256-2806-6624-9596-7855 |
| ADDRESS1 | 1 Old Brewery House |
| ADDRESS2 | Potter Street |
| ADDRESS3 | — |
| POSTCODE | S80 2AQ |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 32 |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| PROPERTY TYPE | Flat |
| BUILT FORM | End-Terrace |
| INSPECTION DATE | 2016-02-16 |
| LOCAL AUTHORITY | E07000171 |
| CONSTITUENCY | E14001079 |
| COUNTY | — |
| LODGEMENT DATE | 2016-02-16 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 41 |
| ENVIRONMENT IMPACT POTENTIAL | 69 |
| ENERGY CONSUMPTION CURRENT | 825 |
| ENERGY CONSUMPTION POTENTIAL | 412 |
| CO2 EMISSIONS CURRENT | 3.2 |
| CO2 EMISS CURR PER FLOOR AREA | 140 |
| CO2 EMISSIONS POTENTIAL | 1.6 |
| LIGHTING COST CURRENT | 25 |
| LIGHTING COST POTENTIAL | 28 |
| HEATING COST CURRENT | 689 |
| HEATING COST POTENTIAL | 120 |
| HOT WATER COST CURRENT | 242 |
| HOT WATER COST POTENTIAL | 109 |
| TOTAL FLOOR AREA | 23 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | 1 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Programmer and appliance thermostats |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 1 |
| NUMBER HEATED ROOMS | 1 |
| LOW ENERGY LIGHTING | 75 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| WALLS DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Programmer and appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | electricity (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | no corridor |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.2 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 1 Old Brewery House, Potter Street |
| LOCAL AUTHORITY LABEL | Bassetlaw |
| CONSTITUENCY LABEL | Bassetlaw |
| POSTTOWN | WORKSOP |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2016-02-16 21:02:23 |
| TENURE | rented (private) |
| FIXED LIGHTING OUTLETS COUNT | 4 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| UPRN | 200001837902 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2016.csv |
| COUNTRY | England |
| REGION | E12000004 |
| Address display | — |
| Nation | ew |