Energy Performance Certificate

5, Silvermere Close, Ramsbottom, BL0 9WH

EPC Report

Energy rating

Current: 69 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 69 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 86 Potential: 86
Field Value
LMK KEY 0253-2896-7082-9608-5481
ADDRESS1 5, Silvermere Close
ADDRESS2 Ramsbottom
ADDRESS3
POSTCODE BL0 9WH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-08-06
LOCAL AUTHORITY E08000002
CONSTITUENCY E14001144
COUNTY
LODGEMENT DATE 2018-08-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 217
ENERGY CONSUMPTION POTENTIAL 116
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 598
HEATING COST POTENTIAL 544
HOT WATER COST CURRENT 338
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 106
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Silvermere Close, Ramsbottom
LOCAL AUTHORITY LABEL Bury
CONSTITUENCY LABEL Bury North
POSTTOWN BURY
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2018-08-07 22:04:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 4210001656
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew