Energy Performance Certificate

1, Halford Road, Ettington, CV37 7TH

EPC Report

Energy rating

Current: 41 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 39 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 73 Potential: 73
Field Value
LMK KEY 0252-2877-7452-9808-2251
ADDRESS1 1, Halford Road
ADDRESS2 Ettington
ADDRESS3
POSTCODE CV37 7TH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-05-03
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001526
COUNTY
LODGEMENT DATE 2018-05-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 262
ENERGY CONSUMPTION POTENTIAL 93
CO2 EMISSIONS CURRENT 9.6
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 1202
HEATING COST POTENTIAL 553
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 154
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.21
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Halford Road, Ettington
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Stratford-on-Avon
POSTTOWN STRATFORD-UPON-AVON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-05-04 08:54:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 10023587563
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000005
Address display
Nation ew