Energy Performance Certificate

Rutlands, Compton Street, SO21 2AS

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 83 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 83 Potential: 83
Field Value
LMK KEY 0248-5947-7340-0122-1920
ADDRESS1 Rutlands
ADDRESS2 Compton Street
ADDRESS3
POSTCODE SO21 2AS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-10-04
LOCAL AUTHORITY E07000094
CONSTITUENCY E14001587
COUNTY
LODGEMENT DATE 2012-10-04
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 89
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 6.1
LIGHTING COST CURRENT 186
LIGHTING COST POTENTIAL 117
HEATING COST CURRENT 1320
HEATING COST POTENTIAL 1333
HOT WATER COST CURRENT 54
HOT WATER COST POTENTIAL 54
TOTAL FLOOR AREA 452
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.23 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.32 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Rutlands, Compton Street
LOCAL AUTHORITY LABEL Winchester
CONSTITUENCY LABEL Winchester
POSTTOWN WINCHESTER
CONSTRUCTION AGE BAND 2012
LODGEMENT DATETIME 2012-10-04 09:24:14
TENURE
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 20
UPRN
UPRN SOURCE
REPORT TYPE 3
Source file certificates-2012.csv
COUNTRY England
REGION E12000008
Address display