Energy Performance Certificate

6, St. Marys Road, Stalham, NR12 9DU

EPC Report

Energy rating

Current: 73 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 68 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 71 Potential: 71
Field Value
LMK KEY 0248-2816-7910-9503-6475
ADDRESS1 6, St. Marys Road
ADDRESS2 Stalham
ADDRESS3
POSTCODE NR12 9DU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2017-09-06
LOCAL AUTHORITY E07000147
CONSTITUENCY E14001396
COUNTY
LODGEMENT DATE 2017-09-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 182
ENERGY CONSUMPTION POTENTIAL 164
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 144
HEATING COST POTENTIAL 126
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 142
TOTAL FLOOR AREA 46
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity and internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, St. Marys Road, Stalham
LOCAL AUTHORITY LABEL North Norfolk
CONSTITUENCY LABEL North Norfolk
POSTTOWN NORWICH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-09-06 14:48:54
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10034812395
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew