Energy Performance Certificate

The Old Mill, Reybridge, Lacock, SN15 2PF

EPC Report

Energy rating

Current: 50 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 53 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 73 Potential: 73
Field Value
LMK KEY 0240-2872-7741-9591-7461
ADDRESS1 The Old Mill
ADDRESS2 Reybridge
ADDRESS3 Lacock
POSTCODE SN15 2PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-04-12
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001168
COUNTY
LODGEMENT DATE 2019-04-30
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 113
CO2 EMISSIONS CURRENT 17.7
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 9.7
LIGHTING COST CURRENT 170
LIGHTING COST POTENTIAL 170
HEATING COST CURRENT 4876
HEATING COST POTENTIAL 3324
HOT WATER COST CURRENT 314
HOT WATER COST POTENTIAL 314
TOTAL FLOOR AREA 478
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated (assumed)
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Old Mill, Reybridge, Lacock
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Chippenham
POSTTOWN CHIPPENHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-04-30 08:40:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 47
LOW ENERGY FIXED LIGHT COUNT 47
UPRN 10014602069
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew