Energy Performance Certificate

38, Sandhurst Avenue, LS8 3QT

EPC Report

Energy rating

Current: 53 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 46 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 82 Potential: 82
Field Value
LMK KEY 0239-2850-7744-9675-2815
ADDRESS1 38, Sandhurst Avenue
ADDRESS2
ADDRESS3
POSTCODE LS8 3QT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2015-04-30
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001320
COUNTY
LODGEMENT DATE 2015-04-30
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 373
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1037
HEATING COST POTENTIAL 551
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.91
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38, Sandhurst Avenue
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds East
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-04-30 14:59:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 72177720
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew