Energy Performance Certificate

2, Five Trees Close, S17 3LY

EPC Report

Energy rating

Current: 52 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 44 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 76 Potential: 76
Field Value
LMK KEY 0239-2816-7197-9595-7945
ADDRESS1 2, Five Trees Close
ADDRESS2
ADDRESS3
POSTCODE S17 3LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-01-16
LOCAL AUTHORITY E08000039
CONSTITUENCY E14001468
COUNTY
LODGEMENT DATE 2015-01-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 377
ENERGY CONSUMPTION POTENTIAL 156
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 747
HEATING COST POTENTIAL 626
HOT WATER COST CURRENT 474
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Five Trees Close
LOCAL AUTHORITY LABEL Sheffield
CONSTITUENCY LABEL Sheffield Hallam
POSTTOWN SHEFFIELD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-01-19 12:37:18
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100050971705
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew