Energy Performance Certificate

66, Overton Drive, E11 2NJ

EPC Report

Energy rating

Current: 10 G | Potential: 38 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 G Current: 10 G 38 F Potential: 38 F

Environmental impact (CO₂)

Current: 11 | Potential: 32
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 Current: 11 32 Potential: 32
Field Value
LMK KEY 0238-9060-7223-7600-9240
ADDRESS1 66, Overton Drive
ADDRESS2
ADDRESS3
POSTCODE E11 2NJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 10
POTENTIAL ENERGY EFFICIENCY 38
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-07-07
LOCAL AUTHORITY E09000026
CONSTITUENCY E14001334
COUNTY
LODGEMENT DATE 2020-07-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 11
ENVIRONMENT IMPACT POTENTIAL 32
ENERGY CONSUMPTION CURRENT 456
ENERGY CONSUMPTION POTENTIAL 257
CO2 EMISSIONS CURRENT 21.2
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 12.2
LIGHTING COST CURRENT 166
LIGHTING COST POTENTIAL 166
HEATING COST CURRENT 4300
HEATING COST POTENTIAL 2645
HOT WATER COST CURRENT 279
HOT WATER COST POTENTIAL 131
TOTAL FLOOR AREA 218
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 61
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 61% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.559
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 66, Overton Drive
LOCAL AUTHORITY LABEL Redbridge
CONSTITUENCY LABEL Leyton and Wanstead
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2020-07-10 07:35:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100022257223
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000007
Address display
Nation ew