Energy Performance Certificate

96, Butlers Way, RH19 4TS

EPC Report

Energy rating

Current: 84 B | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 86 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 97 Potential: 97
Field Value
LMK KEY 0237-9736-3000-0107-3296
ADDRESS1 96
ADDRESS2 Butlers Way
ADDRESS3
POSTCODE RH19 4TS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-06-13
LOCAL AUTHORITY E07000228
CONSTITUENCY E14001212
COUNTY
LODGEMENT DATE 2023-06-13
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 84
ENERGY CONSUMPTION POTENTIAL 13
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 163
LIGHTING COST POTENTIAL 163
HEATING COST CURRENT 456
HEATING COST POTENTIAL 456
HOT WATER COST CURRENT 187
HOT WATER COST POTENTIAL 109
TOTAL FLOOR AREA 95
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 96, Butlers Way
LOCAL AUTHORITY LABEL Mid Sussex
CONSTITUENCY LABEL East Grinstead and Uckfield
POSTTOWN EAST GRINSTEAD
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2023-06-13 15:25:26
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10094499857
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000008
Address display
Nation ew