Energy Performance Certificate

24, Park Road, SS0 7PE

EPC Report

Energy rating

Current: 61 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 52 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 70 Potential: 70
Field Value
LMK KEY 0234-2875-7232-9595-4781
ADDRESS1 24, Park Road
ADDRESS2
ADDRESS3
POSTCODE SS0 7PE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-07-15
LOCAL AUTHORITY E06000033
CONSTITUENCY E14001501
COUNTY
LODGEMENT DATE 2015-07-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 233
ENERGY CONSUMPTION POTENTIAL 133
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 135
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 1247
HEATING COST POTENTIAL 977
HOT WATER COST CURRENT 162
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 172
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24, Park Road
LOCAL AUTHORITY LABEL Southend-on-Sea
CONSTITUENCY LABEL Southend East and Rochford
POSTTOWN WESTCLIFF-ON-SEA
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-07-15 22:04:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100090712014
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew