Energy Performance Certificate

9 Jacob House, Chambers Street, SE16 4EN

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 85 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 85 Potential: 85
Field Value
LMK KEY 0229-3886-7475-9525-5115
ADDRESS1 9 Jacob House
ADDRESS2 Chambers Street
ADDRESS3
POSTCODE SE16 4EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Maisonette
BUILT FORM End-Terrace
INSPECTION DATE 2015-03-26
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001085
COUNTY
LODGEMENT DATE 2015-03-26
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 75
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 13
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 297
HEATING COST POTENTIAL 297
HOT WATER COST CURRENT 104
HOT WATER COST POTENTIAL 104
TOTAL FLOOR AREA 107
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Charging system linked to use of community heating, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.20 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.28 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 9 Jacob House, Chambers Street
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Bermondsey and Old Southwark
POSTTOWN LONDON
CONSTRUCTION AGE BAND 2013
LODGEMENT DATETIME 2015-03-26 14:55:10
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 10090751364
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew