Energy Performance Certificate

19, Shafton View, LS11 9LQ

EPC Report

Energy rating

Current: 22 F | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 35 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 95 Potential: 95
Field Value
LMK KEY 0228-2812-7249-9404-8421
ADDRESS1 19, Shafton View
ADDRESS2
ADDRESS3
POSTCODE LS11 9LQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2014-04-02
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001323
COUNTY
LODGEMENT DATE 2014-04-02
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 591
ENERGY CONSUMPTION POTENTIAL 30
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 42
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 1340
HEATING COST POTENTIAL 297
HOT WATER COST CURRENT 71
HOT WATER COST POTENTIAL 52
TOTAL FLOOR AREA 48
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19, Shafton View
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds South
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-04-02 15:20:18
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 72183294
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew