Energy Performance Certificate

6, The Crescent, YO7 1DE

EPC Report

Energy rating

Current: 18 G | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 16 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 63 Potential: 63
Field Value
LMK KEY 0228-1037-7278-0502-6954
ADDRESS1 6, The Crescent
ADDRESS2
ADDRESS3
POSTCODE YO7 1DE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-08-02
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001544
COUNTY
LODGEMENT DATE 2012-08-02
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 548
ENERGY CONSUMPTION POTENTIAL 175
CO2 EMISSIONS CURRENT 24
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 7.8
LIGHTING COST CURRENT 156
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 3750
HEATING COST POTENTIAL 1438
HOT WATER COST CURRENT 494
HOT WATER COST POTENTIAL 156
TOTAL FLOOR AREA 228
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 15
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 15% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.9
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, The Crescent
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Thirsk and Malton
POSTTOWN THIRSK
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-08-02 12:50:08
TENURE
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 200003298321
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display
Nation ew