Energy Performance Certificate

2, Cwrt y Groes, Tyn-y-Groes, LL32 8TZ

EPC Report

Energy rating

Current: 27 F | Potential: 50 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 50 E Potential: 50 E

Environmental impact (CO₂)

Current: 46 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 67 Potential: 67
Field Value
LMK KEY 0228-1004-6267-7905-6904
ADDRESS1 2, Cwrt y Groes
ADDRESS2 Tyn-y-Groes
ADDRESS3
POSTCODE LL32 8TZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 50
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-03-02
LOCAL AUTHORITY W06000003
CONSTITUENCY W07000083
COUNTY
LODGEMENT DATE 2015-03-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 215
ENERGY CONSUMPTION POTENTIAL 106
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 6.2
LIGHTING COST CURRENT 170
LIGHTING COST POTENTIAL 96
HEATING COST CURRENT 3295
HEATING COST POTENTIAL 2912
HOT WATER COST CURRENT 339
HOT WATER COST POTENTIAL 184
TOTAL FLOOR AREA 232
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 23
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, LPG
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 23% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.66
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Cwrt y Groes, Tyn-y-Groes
LOCAL AUTHORITY LABEL Conwy
CONSTITUENCY LABEL Bangor Aberconwy
POSTTOWN CONWY
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2015-03-06 19:14:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 50000000936
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew