Energy Performance Certificate

19, Brackyn Road, CB1 3PQ

EPC Report

Energy rating

Current: 73 C | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 77 | Potential: 100
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 100 Potential: 100
Field Value
LMK KEY 0220-2819-7276-9674-5235
ADDRESS1 19, Brackyn Road
ADDRESS2
ADDRESS3
POSTCODE CB1 3PQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2014-03-31
LOCAL AUTHORITY E07000008
CONSTITUENCY E14001149
COUNTY
LODGEMENT DATE 2014-03-31
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 100
ENERGY CONSUMPTION CURRENT 191
ENERGY CONSUMPTION POTENTIAL -13
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 0.0
LIGHTING COST CURRENT 27
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 304
HEATING COST POTENTIAL 249
HOT WATER COST CURRENT 81
HOT WATER COST POTENTIAL 48
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19, Brackyn Road
LOCAL AUTHORITY LABEL Cambridge
CONSTITUENCY LABEL Cambridge
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2014-03-31 19:21:59
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200004174852
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew