Energy Performance Certificate

77, Eldon Street, PR1 7PL

EPC Report

Energy rating

Current: 39 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 38 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 80 Potential: 80
Field Value
LMK KEY 0218-2859-7413-9398-4515
ADDRESS1 77, Eldon Street
ADDRESS2
ADDRESS3
POSTCODE PR1 7PL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-09-11
LOCAL AUTHORITY E07000123
CONSTITUENCY E14001433
COUNTY
LODGEMENT DATE 2018-09-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 414
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 6.8
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1166
HEATING COST POTENTIAL 494
HOT WATER COST CURRENT 366
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.98
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77, Eldon Street
LOCAL AUTHORITY LABEL Preston
CONSTITUENCY LABEL Preston
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-09-11 18:43:00
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100010543599
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew