Energy Performance Certificate

11, Westbourne Road, PR8 2HZ

EPC Report

Energy rating

Current: 53 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 49 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 77 Potential: 77
Field Value
LMK KEY 0216-2820-7087-9677-2445
ADDRESS1 11, Westbourne Road
ADDRESS2
ADDRESS3
POSTCODE PR8 2HZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-08-30
LOCAL AUTHORITY E08000014
CONSTITUENCY E14001504
COUNTY
LODGEMENT DATE 2013-08-30
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 239
ENERGY CONSUMPTION POTENTIAL 110
CO2 EMISSIONS CURRENT 18
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 8.2
LIGHTING COST CURRENT 259
LIGHTING COST POTENTIAL 131
HEATING COST CURRENT 3683
HEATING COST POTENTIAL 1882
HOT WATER COST CURRENT 118
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 444
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 12
LOW ENERGY LIGHTING 2
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 2% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Westbourne Road
LOCAL AUTHORITY LABEL Sefton
CONSTITUENCY LABEL Southport
POSTTOWN SOUTHPORT
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-08-30 20:17:26
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 43
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 41130117
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew