Energy Performance Certificate

131, Upper Wickham Lane, DA16 3AQ

EPC Report

Energy rating

Current: 32 F | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 32 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 72 Potential: 72
Field Value
LMK KEY 0214-2816-7539-9397-1801
ADDRESS1 131, Upper Wickham Lane
ADDRESS2
ADDRESS3
POSTCODE DA16 3AQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2013-07-16
LOCAL AUTHORITY E09000004
CONSTITUENCY E14001414
COUNTY
LODGEMENT DATE 2013-07-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 426
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT
CO2 EMISS CURR PER FLOOR AREA
CO2 EMISSIONS POTENTIAL
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1221
HEATING COST POTENTIAL 616
HOT WATER COST CURRENT 345
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 80
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 131, Upper Wickham Lane
LOCAL AUTHORITY LABEL Bexley
CONSTITUENCY LABEL Old Bexley and Sidcup
POSTTOWN WELLING
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-07-16 18:14:15
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100020276145
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000007
Address display
Nation ew