Energy Performance Certificate

44, Trem y Don, CF62 6QL

EPC Report

Energy rating

Current: 2 G | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 2 G Current: 2 G 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 10 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 Current: 10 77 Potential: 77
Field Value
LMK KEY 0209-2882-7054-9627-1601
ADDRESS1 44, Trem y Don
ADDRESS2
ADDRESS3
POSTCODE CF62 6QL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 2
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-05-22
LOCAL AUTHORITY W06000014
CONSTITUENCY W07000110
COUNTY
LODGEMENT DATE 2013-05-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 10
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 686
ENERGY CONSUMPTION POTENTIAL 94
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 134
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 2168
HEATING COST POTENTIAL 522
HOT WATER COST CURRENT 683
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 44, Trem y Don
LOCAL AUTHORITY LABEL Vale of Glamorgan
CONSTITUENCY LABEL Vale of Glamorgan
POSTTOWN BARRY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-05-22 11:37:08
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 64020407
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew