Energy Performance Certificate

88 Delaporte Close, KT17 4AU

EPC Report

Energy rating

Current: 79 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 85 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 85 Potential: 85
Field Value
LMK KEY 0198-3052-0203-4635-3200
ADDRESS1 88 Delaporte Close
ADDRESS2
ADDRESS3
POSTCODE KT17 4AU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2025-07-01
LOCAL AUTHORITY E07000208
CONSTITUENCY E14001227
COUNTY
LODGEMENT DATE 2025-07-04
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 115
ENERGY CONSUMPTION POTENTIAL 115
CO2 EMISSIONS CURRENT 0.9
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 32
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 280
HEATING COST POTENTIAL 280
HOT WATER COST CURRENT 128
HOT WATER COST POTENTIAL 128
TOTAL FLOOR AREA 42
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 88 Delaporte Close
LOCAL AUTHORITY LABEL Epsom and Ewell
CONSTITUENCY LABEL Epsom and Ewell
POSTTOWN EPSOM
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2025-07-04 13:49:22
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100061353446
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew