Energy Performance Certificate

16, Wellington Drive, Middleton St. George, DL2 1FJ

EPC Report

Energy rating

Current: 82 B | Potential: 107 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 107 A Potential: 107 A

Environmental impact (CO₂)

Current: 82 | Potential: 105
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 105 Potential: 105
Field Value
LMK KEY 0174-3807-7339-2990-7331
ADDRESS1 16, Wellington Drive
ADDRESS2 Middleton St. George
ADDRESS3
POSTCODE DL2 1FJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 107
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-07-13
LOCAL AUTHORITY E06000005
CONSTITUENCY E14001519
COUNTY
LODGEMENT DATE 2020-07-13
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 105
ENERGY CONSUMPTION CURRENT 109
ENERGY CONSUMPTION POTENTIAL -30
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 19
CO2 EMISSIONS POTENTIAL -0.6
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 400
HEATING COST POTENTIAL 402
HOT WATER COST CURRENT 99
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 127
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.15 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.1 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler& underfloor, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 16, Wellington Drive, Middleton St. George
LOCAL AUTHORITY LABEL Darlington
CONSTITUENCY LABEL Stockton West
POSTTOWN DARLINGTON
CONSTRUCTION AGE BAND 2020
LODGEMENT DATETIME 2020-07-13 01:03:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10093906860
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000001
Address display
Nation ew