Energy Performance Certificate

47 Butlers & Colonial Wharf, SE1 2PX

EPC Report

Energy rating

Current: 75 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 72 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 81 Potential: 81
Field Value
LMK KEY 0174-3048-2204-5065-7204
ADDRESS1 47 Butlers & Colonial Wharf
ADDRESS2
ADDRESS3
POSTCODE SE1 2PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-04-03
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001085
COUNTY
LODGEMENT DATE 2025-04-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 135
ENERGY CONSUMPTION POTENTIAL 79
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 127
LIGHTING COST POTENTIAL 127
HEATING COST CURRENT 673
HEATING COST POTENTIAL 679
HOT WATER COST CURRENT 202
HOT WATER COST POTENTIAL 124
TOTAL FLOOR AREA 126
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas, Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47 Butlers & Colonial Wharf
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Bermondsey and Old Southwark
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2025-04-03 16:52:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 29
LOW ENERGY FIXED LIGHT COUNT 29
UPRN 200003489670
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew