Energy Performance Certificate

9 Warren Street, PL2 1RG

EPC Report

Energy rating

Current: 27 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 37 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 67 Potential: 67
Field Value
LMK KEY 0170-2809-8044-2007-5521
ADDRESS1 9 Warren Street
ADDRESS2
ADDRESS3
POSTCODE PL2 1RG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-04-01
LOCAL AUTHORITY E06000026
CONSTITUENCY E14001427
COUNTY
LODGEMENT DATE 2023-04-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 371
ENERGY CONSUMPTION POTENTIAL 163
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 98
LIGHTING COST POTENTIAL 107
HEATING COST CURRENT 2650
HEATING COST POTENTIAL 809
HOT WATER COST CURRENT 425
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 129
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9 Warren Street
LOCAL AUTHORITY LABEL Plymouth
CONSTITUENCY LABEL Plymouth Sutton and Devonport
POSTTOWN PLYMOUTH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2023-04-01 12:00:24
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100040500788
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000009
Address display
Nation ew