Energy Performance Certificate

42 STAPLETON ROAD, ORPINGTON, BR6 9TN

EPC Report

Energy rating

Current: 66 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 63 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 85 Potential: 85
Field Value
LMK KEY 0170-2247-7040-2099-4285
ADDRESS1 42 STAPLETON ROAD
ADDRESS2 ORPINGTON
ADDRESS3
POSTCODE BR6 9TN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-04-13
LOCAL AUTHORITY E09000006
CONSTITUENCY E14001417
COUNTY
LODGEMENT DATE 2021-04-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 218
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 545
HEATING COST POTENTIAL 460
HOT WATER COST CURRENT 196
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 73
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 73% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 42 STAPLETON ROAD, ORPINGTON
LOCAL AUTHORITY LABEL Bromley
CONSTITUENCY LABEL Orpington
POSTTOWN ORPINGTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2021-04-13 16:41:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100020477249
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew