Energy Performance Certificate

58, Tiverton Way, CB1 3TU

EPC Report

Energy rating

Current: 51 E | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 42 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 73 Potential: 73
Field Value
LMK KEY 0165-2855-7980-9901-1675
ADDRESS1 58, Tiverton Way
ADDRESS2
ADDRESS3
POSTCODE CB1 3TU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-08-05
LOCAL AUTHORITY E07000008
CONSTITUENCY E14001149
COUNTY
LODGEMENT DATE 2019-08-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 325
ENERGY CONSUMPTION POTENTIAL 132
CO2 EMISSIONS CURRENT 7.2
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 1197
HEATING COST POTENTIAL 699
HOT WATER COST CURRENT 164
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 126
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar, no cylinder thermostat
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 58, Tiverton Way
LOCAL AUTHORITY LABEL Cambridge
CONSTITUENCY LABEL Cambridge
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2019-08-05 21:56:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 200004184405
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew