Energy Performance Certificate

12 HOLLY AVENUE, CARLTON, NG4 1QX

EPC Report

Energy rating

Current: 43 E | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 42 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 55 Potential: 55
Field Value
LMK KEY 0160-2630-4050-2199-7361
ADDRESS1 12 HOLLY AVENUE
ADDRESS2 CARLTON
ADDRESS3
POSTCODE NG4 1QX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-05-10
LOCAL AUTHORITY E07000173
CONSTITUENCY E14001245
COUNTY
LODGEMENT DATE 2021-05-16
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 442
ENERGY CONSUMPTION POTENTIAL 320
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 75
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1085
HEATING COST POTENTIAL 724
HOT WATER COST CURRENT 254
HOT WATER COST POTENTIAL 226
TOTAL FLOOR AREA 65
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 HOLLY AVENUE, CARLTON
LOCAL AUTHORITY LABEL Gedling
CONSTITUENCY LABEL Gedling
POSTTOWN CARLTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-05-16 21:45:53
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100031364677
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000004
Address display
Nation ew