Energy Performance Certificate

1b, East Street, SS4 1DB

EPC Report

Energy rating

Current: 44 E | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 27 | Potential: 43
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 43 Potential: 43
Field Value
LMK KEY 0158-4967-7239-6171-5910
ADDRESS1 1b, East Street
ADDRESS2
ADDRESS3
POSTCODE SS4 1DB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-11-05
LOCAL AUTHORITY E07000075
CONSTITUENCY E14001501
COUNTY
LODGEMENT DATE 2019-11-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 43
ENERGY CONSUMPTION CURRENT 738
ENERGY CONSUMPTION POTENTIAL 504
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 125
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 40
HEATING COST CURRENT 847
HEATING COST POTENTIAL 539
HOT WATER COST CURRENT 170
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 43
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Timber frame, with additional insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.51
FLOOR HEIGHT 2.48
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1b, East Street
LOCAL AUTHORITY LABEL Rochford
CONSTITUENCY LABEL Southend East and Rochford
POSTTOWN ROCHFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-11-30 11:54:09
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100090589335
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew