Energy Performance Certificate

11, Gawith Place, LA9 4EA

EPC Report

Energy rating

Current: 38 F | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 42 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 85 Potential: 85
Field Value
LMK KEY 0158-4097-6248-7737-3910
ADDRESS1 11, Gawith Place
ADDRESS2
ADDRESS3
POSTCODE LA9 4EA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-08-05
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001580
COUNTY
LODGEMENT DATE 2013-08-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 559
ENERGY CONSUMPTION POTENTIAL 129
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 100
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 29
HEATING COST CURRENT 953
HEATING COST POTENTIAL 229
HOT WATER COST CURRENT 54
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 42
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 14
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.04
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Gawith Place
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Westmorland and Lonsdale
POSTTOWN KENDAL
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-08-05 15:32:30
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10003955605
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew