Energy Performance Certificate

104, Park Road, SN7 7DD

EPC Report

Energy rating

Current: 70 C | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 71 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 78 Potential: 78
Field Value
LMK KEY 0158-3950-6299-6834-5960
ADDRESS1 104, Park Road
ADDRESS2
ADDRESS3
POSTCODE SN7 7DD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2014-11-05
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001591
COUNTY
LODGEMENT DATE 2014-11-05
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 189
ENERGY CONSUMPTION POTENTIAL 143
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 444
HEATING COST POTENTIAL 334
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 61
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 96
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 96% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 104, Park Road
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Witney
POSTTOWN FARINGDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-11-05 18:49:56
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 100120917713
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew