Energy Performance Certificate

9, Earls Meadow, CV34 6UA

EPC Report

Energy rating

Current: 80 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 76 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 80 Potential: 80
Field Value
LMK KEY 0155-2802-7825-9223-0005
ADDRESS1 9, Earls Meadow
ADDRESS2
ADDRESS3
POSTCODE CV34 6UA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-02-22
LOCAL AUTHORITY E07000222
CONSTITUENCY E14001566
COUNTY
LODGEMENT DATE 2017-02-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 107
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 6.2
CO2 EMISS CURR PER FLOOR AREA 19
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 205
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 1060
HEATING COST POTENTIAL 1072
HOT WATER COST CURRENT 123
HOT WATER COST POTENTIAL 123
TOTAL FLOOR AREA 323
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 35
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 35% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Earls Meadow
LOCAL AUTHORITY LABEL Warwick
CONSTITUENCY LABEL Warwick and Leamington
POSTTOWN WARWICK
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2017-02-23 07:44:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 34
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 10014036658
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000005
Address display