Energy Performance Certificate

9, Halford Street, Thrapston, NN14 4LA

EPC Report

Energy rating

Current: 1 G | Potential: 36 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 36 F Potential: 36 F

Environmental impact (CO₂)

Current: 6 | Potential: 30
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 6 Current: 6 30 Potential: 30
Field Value
LMK KEY 0148-2848-7540-9126-4411
ADDRESS1 9, Halford Street
ADDRESS2 Thrapston
ADDRESS3
POSTCODE NN14 4LA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 36
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-04-28
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001179
COUNTY
LODGEMENT DATE 2016-04-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 6
ENVIRONMENT IMPACT POTENTIAL 30
ENERGY CONSUMPTION CURRENT 970
ENERGY CONSUMPTION POTENTIAL 496
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 196
CO2 EMISSIONS POTENTIAL 6.1
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 1674
HEATING COST POTENTIAL 1314
HOT WATER COST CURRENT 741
HOT WATER COST POTENTIAL 136
TOTAL FLOOR AREA 56
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Halford Street, Thrapston
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Corby and East Northamptonshire
POSTTOWN KETTERING
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-04-29 09:49:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100031021050
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew