Energy Performance Certificate

1 Randalls Close, Wrestlingworth, SG19 2BZ

EPC Report

Energy rating

Current: 84 B | Potential: 98 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 98 A Potential: 98 A

Environmental impact (CO₂)

Current: 82 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 95 Potential: 95
Field Value
LMK KEY 0145-3848-7153-9596-3401
ADDRESS1 1 Randalls Close
ADDRESS2 Wrestlingworth
ADDRESS3
POSTCODE SG19 2BZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 98
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2016-05-18
LOCAL AUTHORITY E06000056
CONSTITUENCY E14001384
COUNTY
LODGEMENT DATE 2016-05-18
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 88
ENERGY CONSUMPTION POTENTIAL -3
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 51
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 153
HEATING COST POTENTIAL 154
HOT WATER COST CURRENT 109
HOT WATER COST POTENTIAL 54
TOTAL FLOOR AREA 76
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.20 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.09 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Oil: heating oil
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 1 Randalls Close, Wrestlingworth
LOCAL AUTHORITY LABEL Central Bedfordshire
CONSTITUENCY LABEL North Bedfordshire
POSTTOWN SANDY
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2016-05-18 12:34:07
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10093348795
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew